How Long Should A Shallow Well Pump Run

Pressure tank charts

The inrush electric current from starting a motor creates heat in the cadre of the motor. It takes about a infinitesimal of run time for this estrus to transfer to the peel of the motor and be dissipated to the water. Then when the pump shuts off, the motor is still warm, and information technology takes about a minute for the motor to absurd down where it is safe to restart. So a minute on and a minute off has ever been the minimum rule of thumb. Two minutes on and 2 minutes off is just that much better for the motor.

With the one-time conventional pressure tank method, the pressure tank fills at the rate the pump can produce, less the amount of water being used at the time. And then if you have a ten GPM pump and a tank with 10 gallons of draw down, the tank volition make full in 1 minute if no one is using water. If there is an 8 GPM hose running, then the tank will fill at 2 GPM and give 5 minutes of run time to fill the tank. Then because there is even so an 8 GPM hose running, the tank will exist empty in 1.25 minutes and the pump will exist restarted. This is 5 on and i.25 off or 230 cycles per day.

If you only take a 2 GPM hose running, the tank will fill at viii GPM in one.25 minutes, and be off for 5 minutes. That is 1.25 on and 5 off, which is still 230 cycles per day. Either way you are but barely getting the ane minute on or the i minute off that the motor needs. Doubling the size of the tank to 20 gallons of draw downwardly will also double the run and off times just, is all the same 115 cycles per day. The less cycling, the longer the pump will last.

With a CSV the process is a niggling unlike. As long as there is at least i GPM being used, the CSV will keep the pump running continuously. This means absolutely no cycling for systems that apply more i GPM for 24 hours a day, such as with heat pumps. When at that place is no water beingness used, the CSV then fills the force per unit area tank at 1 GPM, from the pressure setting of the CSV to the off setting of the pressure switch.

A four.4 gallon size pressure level tank only holds 1 gallon of water. Every time you use more than ane gallon of water the pump must kickoff. So the pump does not ordinarily need to start while you are rinsing your toothbrush or the ice maker is filling. Withal, the pump will showtime when a toilet is flushed or the shower is running. With a forty/60 force per unit area switch and the CSV set up at fifty PSI, that is only thirty seconds of run time to fill the tank. All the same, when yous flush a toilet, information technology takes virtually 30 seconds for the toilet to refill, then the CSV refills the pressure tank for another 30 seconds, and this gives you lot the required 1 minute run time. When a shower is running, the pump volition continue to run as long as the shower is on, so when the shower is turned off, the CSV will refill the pressure tank in another 30 seconds and shut off the pump. This volition always be more than i minute of run fourth dimension.

The off time required by the motor is as well figured a piffling differently with the CSV. Since the CSV keeps the pump running as long every bit you are using at least 1 GPM, the pump simply shuts off when yous are no longer using water. Since you are no longer using whatsoever water, when the pump shuts off, it stays off until you beginning using water again. This gives you lot much longer than 1 minute of off time. The merely way y'all could make the pump come back on in less than 1 minute, is to shut off all water use, sit and expect 30 seconds for the pump to go off, then quickly open a faucet that uses more than than 2 GPM. This will still requite y'all more than thirty seconds of off time. In reality, if y'all shut off all h2o use, then start using water again in less than xxx seconds, the pump has never shut off and does not bicycle. If you shut off all water use, so restart using water ane minute later, the motor has already had it'southward ane infinitesimal to cool downwards. Merely if yous kickoff using more than than 2 GPM, between thirty and lx seconds after the terminal water outlet was closed, tin you brand the pump stay off less than 1 minute. This may happen on a rare occasion but, it is not something that tin can be repeated, or can even happen ofttimes enough to cause whatever damage to the motor.

With the CSV and a tank that holds one gallon of water, the pump must start every time a toilet is flushed. As long as you flush once more inside thirty seconds of the toilet refilling, the pump does not cycle once more even for multiple flushes. With the CSV and a tank that holds ane gallon of water, the pump must start every fourth dimension the shower is on. Withal, the pump will stay on for the entire time the shower is running, instead of cycling on and off 4 or v times during a shower, equally with a standard tank arrangement. With a CSV and a tank that holds 1 gallon of water, the pump must showtime every time the sprinklers or heat pump is running. However, the pump will stay on the entire time the sprinklers or heat pump is running, instead of cycling hundreds of times per day equally information technology would with a standard pressure tank system.

The pump must start every time a toilet is first flushed. However, the CSV eliminates so many cycles during showers, estrus pump or sprinkler zones, and other long term uses of water, that even though the pump cycles every fourth dimension a toilet is flushed, it is still cycling hundreds of times per twenty-four hours less than a regular force per unit area tank system with a large tank.

A CSV with a 4.4 gallon size tank (i gal draw downwardly) volition cause the pump to cycle almost 40 times per day on the boilerplate house. Using the CSV with a twenty gallon tank (5 gallons of draw down) will cause the pump to cycle about xx times per day on the average business firm. In near cases, this is not enough difference to justify the use of any larger than a 4.4 gallon tank. The way the CSV controls the pump organisation, there is really no justification in using a larger tank. And then if you consider the toll and space needed, at that place is even less justification for using a larger tank.